What We can do?
12 YEARS ELECTRONIC TOOL MANUFACTURERS!
FT-506 compressed air ion nozzle
Category:
Ionizing Air Nozzle
Lables:
隐藏域元素占位
- Product Detail
-
The FT-506 compressed air ion nozzle can eliminate static electricity or dust from objects that are difficult to approach or touch. It is suitable to be installed on the working position as an automatic static elimination device. Its effective distance is 1000mm. It must be used with an OT6007 power supply (the power supply must be purchased separately). The FT-506 compressed gas ionization nozzle has easy installation and work. Stable, strong wind speed, fast elimination of static electricity, adjustable wind speed at the front end of the nozzle.
Section 1: Principle of Action
Non-Thai FT-506 ion tuyere can generate a large number of positive and negative charge air masses, which are blown out at high speed by the compressed air, which can neutralize the charge on the object. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized to achieve For the purpose of eliminating static electricity, high-speed compressed air can also blow away the stubborn dust on the object.
Ionization device: The ionization device forms a stable high-strength electric field under the action of the low current and high voltage generated by the high-voltage generator. The ionized air forms ionic bodies, which are carried out by the high-pressure airflow to the surface of the object to achieve the purpose of neutralizing static electricity and removing dust.
Section 2: Product Features
• Neutralize static electricity quickly.
• The ion airflow covers a large area.
• Wide adjustment range of wind power.
• The nozzle has good grounding protection.
Section 3: Technical Parameters
Operating voltage: 4.6KV
Current consumption: ≤350uA
Air volume: >300CFM (depending on different air pressure)
Operating temperature: 32ºF(0ºC)~122ºF(50ºC)
Ozone amount: 0.03PPM (measured 6 inches before the nozzle)
In addition to static time:
Tester distance Center line
60mm 0.4s
90mm 0.8s
150mm 1.0s
*The static elimination time complies with the ESD standard, and the static elimination time is measured from the test voltage of 5000v~500v.
*The test instrument uses ME268A electrostatic comprehensive tester.
*The test data will vary due to changes in the temperature and humidity of the surrounding air.
Section 4: Safety
4.1 Read the operating instructions before installation and operation.
4.2 It must be grounded reliably before operation.
4.3 Do not operate the nozzle in an flammable and explosive environment.
4.4 Do not repair without authorization.
Section 5: Installation and operation:
Non-Thai FT-506 ion wind nozzle should be used with FT-007 high voltage generator. Insert the end of the tuyere connecting wire into the high-voltage book outlet jack of the high-voltage generator, turn it clockwise to the end, and then connect the ground wire of the tuyere connection to the grounding pole outside the high-voltage generator, and confirm that the grounding is good, the high voltage will be generated. Insert the plug of the generator into a socket with a grounding wire (pay attention to the voltage of the high-voltage generator), fix the air nozzle to a suitable position, connect the compressed gas, and turn on the power of the high-voltage generator to work.
Note: If necessary, you can choose to install an air filter.